Machine fuel tanks

Day tanks and storage tanks for the supply of fuel and lubricating oil

Krampitz BASE icon

TTE – single-walled day tank

The TTE serves as a day tank for supplying units with fuel or lubricating oil. The TTE is also referred to as a receiver tank. Due to its structure and features, it meets the requirements for use in emergency power systems in accordance with VDE 107/108. It is suitable for installation in buildings as well as in system containers. The installation surface must be level, load-bearing and designed as a collecting tray. If there is no collection space available on site, a collection tray must be used. The cubic design of the TTE guarantees optimal use of space. Special dimensions in length, width and height can be easily implemented. The only limits are the approval and transportability.

2
3
4
5
6
7
8
9
10
11
TTE-750
1

G2” sleeve overflow

2

Sleeve G2“ filling

3

Sleeve G2“ level sensor

4

Sleeve G2“ reserve

5

Ø 115 mm burst protection

6

Sleeve G2“ reserve

7

Sleeve G2“ return

8

Sleeve G2“ ventilation

9

G2” sleeve overflow

10

Flange – float level display front (up to TTE-900)

Various measuring systems are used to display the contents of Krampitz tank containers. From purely mechanical to fully electronic. (from TTE-1500 sleeve G2″ – float content display roof)

11

type label

Single-walled day tank TTE-A

The TTE-A-DB serves as a day tank for the Supply of aggregates with fuel or lubricating oil. The TTE-A-DB is also referred to as a template tank. Due to its structure and features, it meets the requirements for use in emergency power systems in accordance with VDE 107/108. It is suitable for installation in buildings as well as in system containers.

The installation surface must be level, load-bearing and designed as a collecting tray. If there is no collection space available on site, a collection tray must be used. The cubic design of the TTE-A-DB guarantees optimal use of space. Special dimensions in length, width and height can be easily implemented. The only limits are the approval and transportability.

TTE-A, single-walled day tank, steel S235JR
PropertyEnvironmentTransportSetting up the Box3D viewVideo
E01 - Single wallE12 - hazardous to groundwaterE19 - FlammableE03 - cleaned and transportableE09 - Indoor useicon 3dyoutube icon

E1 single-walled

E12 hazardous to groundwater

E19
Flash point >55°C

E3 cleaned and transportable

E9 interior use

3D view

Video

TTE-A, single-walled day tank, steel S235JR
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
TTE-100TTE-A-100-DBZ-38.11 8610055052553038
TTE-250TTE-A-250-DBZ-38.11 862501.30052553078
TTE-500TTE-A-500-DBZ-38.11 864701.550775530115
TTE-750TTE-A-750-DBZ-38.11 867301.550775780153
TTE-990TTE-A-990-DBZ-38.11 869802.050775780192
TTE-1500TTE-A-1500-DBZ-38.11 861.7902.0501.0001.030336
TTE-1950TTE-A-1950-DBZ-38.11 862.2602.0501.2501.030428

Single-walled day tank TTE-B-EBZ

The TTE-B-EBZ serves as a day tank for supplying units with fuel and lubricating oil. The TTE-B-EBZ is also known as a storage tank. Due to its structure and features, it meets the requirements for use in emergency power systems in accordance with VDE 107/108. It is suitable for installation in buildings as well as in system containers.

The installation surface must be level, load-bearing and designed as a collecting tray. If there is no collection space available on site, a collection tray must be used. The cubic design of the TTE-B-EBZ guarantees optimal use of space.

TTE-B-EBZ, single-walled day tank, steel S235JR, EBZ = earthquake zone 1-3
PropertyEnvironmentTransportSetting up the Box3D viewVideo
E01 - Single wallE12 - hazardous to groundwaterE19 - FlammableE03 - cleaned and transportableE09 - Indoor useicon 3dyoutube icon

E1 single-walled

E12 hazardous to groundwater

E19
Flash point >55°C

E3 cleaned and transportable

E9 interior use

3D view

Video

TTE-B-EBZ, single-walled day tank, steel S235JR, EBZ = earthquake zone 1-3
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
TTE-100TTE-B-100-EBZZ-38.11 8610055052553038
TTE-250TTE-B-250-EBZZ-38.11 862501.30052553078
TTE-500TTE-B-500-EBZZ-38.11 864701.550775530115
TTE-750TTE-B-750-EBZZ-38.11 867301.550775780153
TTE-990TTE-B-990-EBZZ-38.11 869802.050775780192

Single-walled day tank TTE-B-UR

The TTE-B-UR serves as a day tank for supplying aggregates with urea. The TTE-B-UR is also referred to as a storage tank. Due to its structure and features, it meets the requirements for use in emergency power systems in accordance with VDE 107/108. It is suitable for installation in buildings as well as in system containers.

The installation surface must be level, load-bearing and designed as a collecting tray. If there is no collection space available on site, a collection tray must be used. The cubic design of the TTE-B-UR guarantees optimal use of space.

TTE-B-UR, single-wall day tank, urea, steel S235JR, seismic zone 1-3
PropertyEnvironmentTransportSetting up the Box3D viewVideo
E01 - Single wallE12 - hazardous to groundwaterE19 - FlammableE14 - special interior coatingE03 - cleaned and transportableE09 - Indoor useicon 3dyoutube icon

E1 single-walled

E12 hazardous to groundwater

E19
Flash point >55°C

E14 inside
Special coating

E3 cleaned and transportable

E9 interior use

3D view

Video

TTE-B-UR, single-wall day tank, urea, steel S235JR, seismic zone 1-3
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
TTE-500TTE-B-500-URZ-38.11 864701.550775530115
TTE-750TTE-B-750-URZ-38.11 867301.550775780153
TTE-990TTE-B-990-URZ-38.11 869802.050775780192
TTE-1500TTE-B-SPECIAL-URZ-38.11 861.7902.0501.0001.030336

Single-walled day tank TTE-B-VA

The TTE-B-VA serves as a day tank for supplying units with fuel, urea and lubricating oil. The TTE-B-VA is also known as a storage tank. Due to its structure and features, it meets the requirements for use in emergency power systems in accordance with VDE 107/108. It is suitable for installation in buildings as well as in system containers.

The installation surface must be level, load-bearing and designed as a collecting tray. If there is no collection space available on site, a collection tray must be used. The cubic design of the TTE-B-VA guarantees optimal use of space.

TTE-B-VA, single-walled day tank, stainless steel VA, earthquake zone 1-3
PropertyEnvironmentTransportSetting up the Box3D viewVideo
E01 - Single wallE12 - hazardous to groundwaterE19 - FlammableE03 - cleaned and transportableE09 - Indoor useicon 3dyoutube icon

E1 single-walled

E12 hazardous to groundwater

E19
Flash point >55°C

E3 cleaned and transportable

E9 interior use

3D view

Video

TTE-B-VA, single-walled day tank, stainless steel VA, earthquake zone 1-3
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
TTE-100TTE-B-100-VAZ-38.11 8610055052553038
TTE-250TTE-B-250-VAZ-38.11 862501.30052553078
TTE-500TTE-B-500-VAZ-38.11 864701.550775530115
TTE-750TTE-B-750-VAZ-38.11 867301.550775780153
TTE-990TTE-B-990-VAZ-38.11 869802.050775780192

Single-walled day tank TTE-C-EBZ

The TTE-C-EBZ serves as a day tank for supplying units with fuel and lubricating oil. The TTE-C-EBZ is also referred to as a storage tank. Due to its structure and features, it meets the requirements for use in emergency power systems in accordance with VDE 107/108. It is suitable for installation in buildings as well as in system containers.

The installation surface must be level, load-bearing and designed as a collecting tray. If there is no collection space available on site, a collection tray must be used. The cubic design of the TTE-C-EBZ guarantees optimal use of space.

TTE-C-EBZ, single-walled day tank, steel S235JR, EBZ = earthquake zone 1-3
PropertyEnvironmentTransportSetting up the Box3D viewVideo
E01 - Single wallE12 - hazardous to groundwaterE19 - FlammableE03 - cleaned and transportableE09 - Indoor useicon 3dyoutube icon

E1 single-walled

E12 hazardous to groundwater

E19
Flash point >55°C

E3 cleaned and transportable

E9 interior use

3D view

Video

TTE-C-EBZ, single-walled day tank, steel S235JR, seismic zone 1-3
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
TTE-1500TTE-C-1500-EBZZ-38.11 861.7902.0501.0001.030336
TTE-1950TTE-C-1950-EBZZ-38.11 862.2602.0501.2501.030428

Single-walled day tank TTE-C-UR

The TTE-C-UR serves as a day tank for supplying aggregates with urea. The TTE-C-UR is also referred to as a storage tank. Due to its structure and features, it meets the requirements for use in emergency power systems in accordance with VDE 107/108. It is suitable for installation in buildings as well as in system containers.

The installation surface must be level, load-bearing and designed as a collecting tray. If there is no collection space available on site, a collection tray must be used. The cubic design of the TTE-C-UR guarantees optimal use of space.

TTE-C-UR, single-wall day tank, urea, steel S235JR, seismic zone 1-3
PropertyEnvironmentTransportSetting up the Box3D viewVideo
E01 - Single wallE12 - hazardous to groundwaterE19 - FlammableE14 - special interior coatingE03 - cleaned and transportableE09 - Indoor useicon 3dyoutube icon

E1 single-walled

E12 hazardous to groundwater

E19
Flash point >55°C

E14 inside
Special coating

E3 cleaned and transportable

E9 interior use

3D view

Video

TTE-C-UR, single-wall day tank, urea, steel S235JR, seismic zone 1-3
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
TTE-1500TTE-C-1500-URZ-38.11 861.7902.0501.0001.030336
TTE-1950TTE-C-1950-URZ-38.11 862.2602.0501.2501.030428

Single-walled day tank TTE-C-VA

The TTE-C-VA serves as a day tank for supplying units with fuel, urea and lubricating oil. The TTE-C-VA is also known as a storage tank. Due to its structure and features, it meets the requirements for use in emergency power systems in accordance with VDE 107/108. It is suitable for installation in buildings as well as in system containers.

The installation surface must be level, load-bearing and designed as a collecting tray. If there is no collection space available on site, a collection tray must be used. The cubic design of the TTE-C-VA guarantees optimal use of space.

TTE-C-VA, single-walled day tank, stainless steel VA, earthquake zone 1-3
PropertyEnvironmentTransportSetting up the Box3D viewVideo
E01 - Single wallE12 - hazardous to groundwaterE19 Flash point greater than 55°CFor highly flammable mediaicon cleaned transportableicon indoor installationicon 3dyoutube icon

E1 single-walled

E12 hazardous to groundwater

E19
Flash point >55°C

E7 – <55°C

E3 cleaned and transportable

E9 interior use

3D view

Video

TTE-C-VA, single-walled day tank, stainless steel VA, earthquake zone 1-3
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
TTE-1500TTE-C-1500-VAZ-38.11 861.7902.0501.0001.030336
TTE-1950TTE-C-1950-VAZ-38.11 862.2602.0501.2501.030428

Single-walled day tank TTE-XL

The TTE-XL serves as Day tank for the Supply of aggregates with fuel or lubricating oil. Due to its structure and features, the tank meets the requirements for use in emergency power systems in accordance with VDE 107/108. The TTE-XL can due to its volume also as a storage tank act. It is suitable for installation in buildings as well as in system containers.

The installation surface must be level, load-bearing and designed as a collecting tray. If there is no collection space available on site, a collection tray must be used. The cubic design of the TTEXL guarantees one optimal use of space. Special dimensions in length, width and height can be easily implemented. The only limits are the transportability.

TTE-XL - single-walled day tank
PropertyEnvironmentTransportSetting up the Box3D viewVideo
E01 - Single wallE12 - hazardous to groundwaterE19 - FlammableE03 - cleaned and transportableE09 - Indoor useicon 3dyoutube icon

E1 single-walled

E12 hazardous to groundwater

E19
Flash point >55°C

E3 cleaned and transportable

E9 interior use

3D view

Video

TTE-XL - single-walled day tank
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
TTE-XL-2500TTE-XL-2500Z-38.11 1272.8002.1351.2601.450530
TTE-XL-3000TTE-XL-3000Z-38.11 1273.3002.1351.5101.450595
TTE-XL-4000TTE-XL-4000Z-38.11 1273.9502.1351.5101.700660
TTE-XL-5000TTE-XL-5000Z-38.11 1275.0003.1351.5101.450810

KTD-TT (Old: TTD) – Double-walled day tank

The KTD-TT (old: TTD) serves as a day tank for supplying units with fuel or lubricating oil. It is also referred to as a storage tank. This tank is suitable for installation in buildings as well as in plant containers. Due to its double-walled construction, no collecting tray is required on site.

The installation surface must be level and stable. The cubic design of the KTD-TT (old: TTD) guarantees optimal use of space. If necessary, the dimensions can be changed within the maximum values ​​as shown in the table below. The only limits here are the approval and transportability.

KTD-TT (Old: TTD) – Double-walled day tank
PropertyEnvironmentTransportSetting up the BoxVideo
icon E2 double-walledicon groundwater hazardous mediaE19 - Flammableicon cleaned transportableicon indoor installationicon 3dyoutube icon

E2 double-walled

E12 hazardous to groundwater

E19 flammable

E3 cleaned and transportable

E9 interior use

3D view

Video

TTD – double-walled day tank
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
TTD-250KTD-TT-250-DB
(OLD: TTD-250)
Z-38.12 232301.280500630133
TTD-500KTD-TT-500-DB
(OLD: TTD-500)
Z-38.12 234401.530750630186
TTD-750KTD-TT-750-DB
(OLD: TTD-750)
Z-38.12 237001.530750880248
TTD-990KTD-TT-990-DB
(OLD: TTD-990)
Z-38.12 239402.030750880316
TTD-1500KTD-TT-1500-DB
(OLD: TTD-1500)
Z-38.12 231.7302.0301.0001.130524
TTD-1950KTD-TT-1950-DB
(OLD: TTD-1950)
Z-38.12 232.1902.0301.2501.130658

Daily tanks – current articles:

Krampitz day tank TTE equipment package Emden

Krampitz day tank TTE equipment package Emden

The TTE Emden equipment package contains three AE 100 level sensors. In addition, there is an AE 200 level sensor with the associated AE-201 evaluation unit for the electrical overfill protection. In addition, there is a barrel plug and a Z-PK pump combination that enables the TTE day tanks to be filled from a barrel.
TTE equipment package Elmshorn

TTE day tank equipment package Elmshorn

The TTE Elmshorn equipment package contains two level sensors,…
TTE day tank equipment package Eisenach

TTE day tank equipment package Eisenach and flow diagrams

The TTE Eisenach equipment package contains three level sensors…
Krampitz double-walled day tanks TTD

Krampitz double-walled day tanks KTD-TT (old: TTD)

Our double-walled day tanks KTD-TT (old: TTD) are…
Day tank TTE-XL

Krampitz single-walled day tanks TTE XL

Our single-walled day tanks TTE-XL are made of stainless steel or…
Day tanks TTE

Krampitz single-walled day tanks TTE

 Our single-walled day tanks TTE are made of stainless steel or…
Machine tanks with collecting tray

Machine tanks with collecting tray

Krampitz machine tanks TTE-300 special with collecting tray machine tanks…
professional supply of combustion engines

Series: Supply of combustion engines

Supply of combustion engines Presentation concept: professional…
Krampitz oil supply system

Professional lubricating oil supply

Professional lubricating oil supply for large gas engines, diesel engines and large gas compressors...
Packaged day tanks ready for delivery

KTE – single-walled storage tank

The KTE is used to store water, aqueous solutions and wastewater in accordance with the approval. Not suitable for water-polluting media. The characteristic feature of the tank container is its single-walled, cubic structure. This guarantees effective use of space. The installation surface must be level and stable. The KTE can be easily transported using a forklift, pallet truck or crane.

KTE - single-walled storage tank
PropertyEnvironmentTransportSetting up the BoxVideo
icon E1 single-walledicon groundwater hazardous mediaE19 Flash point greater than 55°Cicon cleaned transportableicon indoor installationicon 3dyoutube icon

E1 single-walled

E12 hazardous to groundwater

E19 flammable

E3 cleaned and transportable

E9 interior use

3D view

Video

KTE - single-walled storage tank
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
KTE-950-IAKTE-950Z-38.11 1439701.0007601.700280
KTE-1500-IAKTE-1500Z-38.11 1431.4501.5007601.700360
KTE-2000-IAKTE-2000Z-38.11 1431.9501.5001.0101.700430
KTE-2500-IAKTE-2500Z-38.11 1432.6502.0001.0101.700530
KTE-3000-IAKTE-3000Z-38.11 1433.3502.0001.2601.700620
KTE-4000-IAKTE-4000Z-38.11 1434.0002.0001.5101.700680
KTE-4500-IAKTE-4500Z-38.11 1434.2352.2501.7001.650740
KTE-6000-IAKTE-6000Z-38.11 1435.9003.0001.5301.750970
KTE-9000-IAKTE-9000Z-38.11 1439.0003.4002.0301.7501.270
KTE-10000-IAKTE-10000Z-38.11 14310.2203.0002.0302.2001.420
KTE-12000-IAKTE-12000Z-38.11 14312.0003.5002.0302.2501.730
KTE-15000-IAKTE-15000Z-38.11 14313.7004.0002.0302.2501.920
KTE-20000-IAKTE-20000Z-38.11 14318.9005.5002.0302.2502.720
KTE-25000-IAKTE-25000Z-38.11 14324.1007.0002.0302.2503.100
KTE-30000-IAKTE-30000Z-38.11 14327.4008.0002.0302.2503.600
KTE-40000-IAKTE-40000Z-38.11 14343.60010.5002.4302.2504.900
KTE-50000-IAKTE-50000Z-38.11 14349.90012.0002.4302.2505.600

KTD – double-walled storage tank

The KTD is used to store heating oil, diesel, mineral oil (used fresh and lubricating oil) or other water-polluting liquids in accordance with the approval. It is also known as a storage tank. Its double-walled steel structure guarantees the highest safety standards. An additional collecting tray is not required. The cubic design guarantees optimal use of space. The KTD is suitable for installation in buildings as well as in system containers. The installation surface must be level and stable. The KTD can be easily transported using a forklift, pallet truck or crane.

KTD - double-walled storage tank
PropertyEnvironmentTransportSetting up the Box
icon E2 double-walledicon groundwater hazardous mediaE19 Flash point greater than 55°Cicon cleaned transportableicon indoor installationicon 3dyoutube icon

E2 double-walled

E12 hazardous to groundwater

E19
Flash point >55°C

E3 cleaned and transportable

E9 interior use

3D view

Video
KTD - double-walled storage tank
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
KTD-950KTD-950-DB-01Z-38.12 239301.0007601.950450
KTD-1500KTD-1500-DB-01Z-38.12 231.4401.5007601.950560
KTD-2000KTD-2000-DB-01Z-38.12 231.9301.5001.0101.950680
KTD-2500KTD-2500-DB-01Z-38.12 232.6402.0001.0101.950795
KTD-3000-DB-01KTD-3000-DB-01Z-38.12 233.3002.0001.2601.950920
KTD-4000KTD-4000-DB-01Z-38.12 233.9502.0001.5101.9501.080
KTD-4500KTD-4500-DB-01Z-38.12 234.7002.5001.5101.9501.180
KTD-6000KTD-6000-DB-01Z-38.12 235.7003.0001.5301.9501.460
KTD-9000KTD-9000-DB-01Z-38.12 238.9003.4002.0301.9501.840
KTD-10000KTD-10000-DB-01Z-38.12 2310.0803.0002.0002.4501.850
KTD-12000KTD-12000-DB-01Z-38.12 2311.8003.5002.0302.4502.280
KTD-15000KTD-15000-DB-01Z-38.12 2313.6004.0002.0302.4502.490
KTD-20000KTD-20000-DB-01Z-38.12 2318.7005.5002.0302.4503.460
KTD-25000KTD-25000-DB-01Z-38.12 2323.8007.0002.0302.4504.200
KTD-30000KTD-30000-DB-01Z-38.12 2327.4008.0002.0302.4504.750
KTD-40000KTD-40000-DB-01Z-38.12 2343.60010.5002.4302.4506.800
KTD-50000KTD-50000-DB-01Z-38.12 2349.90012.0002.4302.4507.600

KTD-FL – double-walled, flat storage tank

Flat double-walled fuel storage tank container for placing machine sets and installing them in machine containers.

KTD-FL – double-walled, flat storage tank
PropertyEnvironmentTransportSetting up the BoxVideo
E02 - Double-walledE12 - hazardous to groundwaterE19 - FlammableE03 - cleaned and transportableE09 - Indoor useicon 3dyoutube icon

E2 double-walled

E12 hazardous to groundwater

E19 Flash point >55°C

E3 cleaned and transportable

E9 interior use

3D view

Video
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
KTD-FLKTD-FL-2000Z-38.12 23
KTD-FLKTD-FL-4000Z-38.12 23
KTD-FLKTD-FL-6000Z-38.12 23
KTD-FLKTD-FL-8000Z-38.12 23
KTD-FLKTD-FL-10000Z-38.12 23
KTD-FLKTD-FL-12000Z-38.12 23

KTD-FAA – double-walled storage tank, outdoor installation

The KTD-F is a double-walled storage tank made of heavy-duty steel and is used to store water-polluting media such as diesel, heating oil and gasoline. It is equipped with an approved vacuum leak detection system. The installation takes place on a flat, load-bearing surface. The KTD-F can be easily transported using a forklift or crane. The KTD-F comes with extensive basic equipment that enables immediate use.

Optional options include stainless steel versions, electric heating and a heating register for using process heat. The KTD-F is manufactured from steel S38.12 JR in accordance with the general building regulations approval Z-312-235 and must be equipped with a vacuum leak detector.

Advantages of this system are:

  • high static strength and double-walled construction
  • Newly designed floor assembly for fixing the foundation using adhesive anchors
  • Optimal space-content ratio thanks to cubic design
  • Seal the tank openings with a hood to protect against moisture and vandalism
KTD-FAA, double-walled storage tank, outdoor installation, steel S235JR
PropertyEnvironmentTransportSetting up the Box
E02 - Double-walledE12 - hazardous to groundwaterE19 - FlammableE03 - cleaned and transportableE08 - Outdoor useicon 3dyoutube icon

E2 double-walled

E12 hazardous to groundwater

E19 Flash point >55°C

E3 cleaned and transportable

E8 outdoor use

3D view

Video

ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkg (approx.)PDFMail
KTD-FA-1-AZ-38.12 3121025101012201800700
KTD-FA-1.5-AZ-38.12 3121560152012201800850
KTD-FA-2.5-AZ-38.12 31225102020122020001110
KTD-FA-5-AZ-38.12 31251402020172024001490
KTD-FA-7-AKTD-FA-7-AZ-38.12 31269502020202024001770
KTD-FA-10-AZ-38.12 312102803030202024002430
KTD-FA-15-AZ-38.12 312139104030202024002950
KTD-FA-20-AZ-38.12 312190505530202024004170
KTD-FA-30-AZ-38.12 312278208030202024005130
KTD-FA-40-AZ-38.12 3123839011030202024006790

KTD-FAB – double-walled storage tank, outdoor installation including 80 mm thermal insulation

The KTD-F is a double-walled storage tank made of heavy-duty steel and is used to store water-polluting media such as diesel, heating oil and gasoline. It is equipped with an approved vacuum leak detection system. The installation takes place on a flat, load-bearing surface. The KTD-F can be easily transported using a forklift or crane. The KTD-F comes with extensive basic equipment that enables immediate use.

Optional options include stainless steel versions, electric heating and a heating register for using process heat. The KTD-F is manufactured from steel S38.12 JR in accordance with the general building regulations approval Z-312-235 and must be equipped with a vacuum leak detector.

Advantages of this system are:

  • high static strength and double-walled construction
  • Newly designed floor assembly for fixing the foundation using adhesive anchors
  • Optimal space-content ratio thanks to cubic design
  • Seal the tank openings with a hood to protect against moisture and vandalism
KTD-FAB, double-walled storage tank, outdoor installation, steel S235JR, including thermal insulation 80 mm
PropertyEnvironmentTransportSetting up the Box
E02 - Double-walledE12 - hazardous to groundwaterE19 - FlammableE03 - cleaned and transportableE20 - thermal insulationE08 - Outdoor useyoutube icon

E2 double-walled

E12 hazardous to groundwater

E19 Flash point >55°C

E3 cleaned and transportable

E20 thermally insulated

E8 outdoor use

Video
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkg (approx.)PDFMail
KTD-FA-1-BZ-38.12 3121025118013801820835
KTD-FA-1.5-BZ-38.12 31215601680138018201030
KTD-FA-2.5-BZ-38.12 31225102180138019501335
KTD-FA-5-BZ-38.12 31251402180188024051835
KTD-FA-7-BKTD-FA-7-BZ-38.12 31269502180238024052205
KTD-FA-10-BZ-38.12 312102803180238024053000
KTD-FA-15-BZ-38.12 312139104180238024053655
KTD-FA-20-BZ-38.12 312190505680238024055085
KTD-FA-30-BZ-38.12 312278208180238024056375
KTD-FA-40-BZ-38.12 3123839011180238024058425

KTD-FAC – double-walled storage tank, outdoor installation including internal coating with urea

The KTD-F is a double-walled storage tank made of heavy-duty steel and is used to store water-polluting media such as diesel, heating oil and gasoline. It is equipped with an approved vacuum leak detection system. The installation takes place on a flat, load-bearing surface. The KTD-F can be easily transported using a forklift or crane. The KTD-F comes with extensive basic equipment that enables immediate use.

Optional options include stainless steel versions, electric heating and a heating register for using process heat. The KTD-F is manufactured from steel S38.12 JR in accordance with the general building regulations approval Z-312-235 and must be equipped with a vacuum leak detector.

Advantages of this system are:

  • high static strength and double-walled construction
  • Newly designed floor assembly for fixing the foundation using adhesive anchors
  • Optimal space-content ratio thanks to cubic design
  • Seal the tank openings with a hood to protect against moisture and vandalism
KTD-FAC, double-walled storage tank, outdoor installation, steel S235JR, including inner coating with urea
PropertyEnvironmentTransportSetting up the Box
E02 - Double-walledE12 - hazardous to groundwaterE19 - FlammableE03 - cleaned and transportableE14 - special interior coatingE08 - Outdoor useyoutube icon

E2 double-walled

E12 hazardous to groundwater

E19 Flash point >55°C

E3 cleaned and transportable

E14 internal coating
urea

E8 outdoor use

Video
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkg (approx.)PDFMail
KTD-FA-1-CZ-38.12 3121025101012201800908
KTD-FA-1.5-CZ-38.12 31215601520122018001107
KTD-FA-2.5-CZ-38.12 31225102020122020001443
KTD-FA-5-CZ-38.12 31251402020172024001948
KTD-FA-7-CZ-38.12 31269502020222024002321
KTD-FA-10-CZ-38.12 312102803030222024003180
KTD-FA-15-CKTD-FA-15-CZ-38.12 312139104030222024003863
KTD-FA-20-CZ-38.12 312190505530222024005441
KTD-FA-30-CZ-38.12 312278208030222024006723
KTD-FA-40-CZ-38.12 3123839011030222024008896

KTD-FAD – double-walled storage tank – outdoor installation in earthquake zones 1-3

The KTD-F is a double-walled storage tank made of heavy-duty steel and is used to store water-polluting media such as diesel, heating oil and gasoline. It is equipped with an approved vacuum leak detection system. The installation takes place on a flat, load-bearing surface. The KTD-F can be easily transported using a forklift or crane. The KTD-F comes with extensive basic equipment that enables immediate use.

Optional options include stainless steel versions, electric heating and a heating register for using process heat. The KTD-F is manufactured from steel S38.12 JR in accordance with the general building regulations approval Z-312-235 and must be equipped with a vacuum leak detector.

Advantages of this system are:

  • high static strength and double-walled construction
  • Newly designed floor assembly for fixing the foundation using adhesive anchors
  • Optimal space-content ratio thanks to cubic design
  • Seal the tank openings with a hood to protect against moisture and vandalism
KTD-FAD - double-walled storage tank, outdoor installation, steel S235JR, seismic zone 1-3
PropertyEnvironmentTransportSetting up the Box
E02 - Double-walledE12 - hazardous to groundwaterE19 - FlammableE03 - cleaned and transportableE23 - EarthquakeE08 - Outdoor useyoutube icon

E2 double-walled

E12 hazardous to groundwater

E19 Flash point >55°C

E3 cleaned and transportable

E23 Seismic Zones 1-3

E8 outdoor use

Video
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkg (approx.)PDFMail
KTD-FA-1-DZ-38.12 3121025101012201800700
KTD-FA-1.5-DZ-38.12 3121560152012201800850
KTD-FA-2.5-DZ-38.12 31225102020122020001110
KTD-FA-5-DZ-38.12 31251402020172024001490
KTD-FA-7-DZ-38.12 31269502020202024001770
KTD-FA-10-DZ-38.12 312102803030202024002430
KTD-FA-15-DKTD-FA-15-DZ-38.12 312139104030202024003059
KTD-FA-20-DZ-38.12 312190505530202024004279
KTD-FA-30-DZ-38.12 312278208030202024005348
KTD-FA-40-DZ-38.12 3123839011030202024007117

KTD-F-TI-EBZ – double-walled storage tank, Freeland, thermally insulated

The KTD-F-Ti is used for the storage of mineral oils, lubricating oils, aqueous hand solution or other media that may have problems with pour point and viscosity. Here the medium is kept flowing by using a tank heater. It is also approved for use in regions with earthquake zone 1. The KTD-F-Ti is manufactured according to the general building regulations approval Z-38.12-312.

The KTD-F-TI for storing heating oil, diesel, mineral oil, vegetable oil and media that need to be heated. The Freeland is designed for installation outside buildings or outdoors. The installation takes place on a flat, load-bearing concrete slab. The Freeland can be equipped with high-quality interior coatings and can be easily transported using a forklift or crane. The characteristic feature of the tank container is its double-walled, cubic structure and its high-quality thermal insulation.

Advantages of this system are:

  • Safety: high static strength
  • Double-walled construction with vacuum leak detector and thermal insulation
  • Storage capacity: optimal space-content ratio thanks to cubic design
  • Protected arrangement of the equipment in the double-walled tank body
  • Low investment costs: there is no need for an additional collecting tray, a stable surface is sufficient
ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkg (approx.)PDFMail
KTD-F-TI-EBZ1-50KTD-F-TI-EBZ1-50Z-38.12 31245.00012.0102.4202.4509.200
KTD-F-TI-EBZ1-50KTD-F-TI-EBZ1-60Z-38.12 31254.60012.0102.4202.9509.800
KTD-F-TI-EBZ1-50KTD-F-TI-EBZ1-75Z-38.12 31258.40012.0102.4202.45010.400
KTD-F-TI-EBZ1-50KTD-F-TI-EBZ1-96Z-38.12 31273.60015.0103.0202.45012.700

KCD-FL – double-walled, flat storage tank container

Flat fuel storage tank container Double-walled for setting up machine containers on the tank roof in standard ISO width.

The double-walled, extra-flat steel fuel storage tank container for storing diesel fuel for supplying diesel generators is equipped with a heavy container frame that can accommodate a 20ft or 40ft machine container. This creates a space-saving overall system in which the diesel generator is located in the machine container directly on the extra-flat fuel storage tank container.

The KCD-FL offers a compact design of the entire system and enables quick system assembly on site. The service section with dome entry, connecting flanges with 2" sockets are arranged outside the container frame in a hood element. This is easy to install and service and makes planning the entire system easy. In addition to the hood element, a Krampitz fuel cleaning and care system (KRP) can be installed in the weather protection housing in the service section if necessary. Optional accessories can be installed here. The storage tank container is equipped with vacuum leak monitoring.

KCD-FL – double-walled, flat storage tank container
PropertyEnvironmentTransportSetting up the Box
E02 - Double-walledE12 - hazardous to groundwaterE10 - diesel/heating oilE03 - cleaned and transportableE08 - Outdoor useicon 3dyoutube icon

E2 double-walled

E12 hazardous to groundwater

E10 diesel/heating oil

E3 cleaned and transportable

E8 outdoor use

3D view

Video

ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
KCD-FLKCD-FL-20ft/500Z-38.12 3127.2167.0582.4381.2693.180
KCD-FLKCD-FL-20ft/750Z-38.12 31210.8237.0582.4381.5193.525
KCD-FLKCD-FL-20ft/1000Z-38.12 31214.6567.0582.4381.7693.879
KCD-FLKCD-FL-40ft/500Z-38.12 31213.71513.1922.4381.2695.636
KCD-FLKCD-FL-40ft/750Z-38.12 31220.57313.1922.4381.5196.142
KCD-FLKCD-FL-40ft/1000Z-38.12 31227.84213.1922.4381.7696.823

KCD-FL-XL – storage tank container, double-walled, flat, extra wide

Flat extra wide fuel storage tank container double-walled XL for installing machine containers on the tank roof with extra-wide dimensions. The extra-wide (3.000 mm) double-walled, extra-flat steel fuel storage tank container for storing diesel fuels is intended for supplying diesel generators. This storage tank container is equipped with a heavy container frame, which is used to accommodate an extra-wide machine housing on the storage tank container. This enables space-saving overall installations. The KCD-FL-XL offers a compact design and allows for quick system assembly on site. The service section with dome entry, connection flanges with 2" sleeves is arranged outside the ISO container frame. This is easy to assemble and service and makes planning the entire system simple. In addition to the hood element, a Krampitz fuel cleaning system and fuel care system (KRP) can be installed in the weatherproof housing on the service section if required.

KCD-FL-XL – Extra-wide storage tank container, double-walled, flat
PropertyEnvironmentTransportSetting up the Box
E02 - Double-walledE12 - hazardous to groundwaterE10 - diesel/heating oilE03 - cleaned and transportableE08 - Outdoor useyoutube icon

E2 double-walled

E12 hazardous to groundwater

E10 diesel/heating oil

E3 cleaned and transportable

E8 outdoor use

Video

ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
KCD-FL-XLKCD-FL-XL-20ft/500Z-38.12 3129.0387.0583.0001.2693.709
KCD-FL-XLKCD-FL-XL-20ft/750Z-38.12 31213.5627.0583.0001.5194.040
KCD-FL-XLKCD-FL-XL-20ft/1000Z-38.12 31218.3697.0583.0001.7694.432
KCD-FL-XLKCD-FL-XL-40ft/500Z-38.12 31217.16613.1923.0001.2696.604
KCD-FL-XLKCD-FL-XL-40ft/750Z-38.12 31225.74913.1923.0001.5196.991
KCD-FL-XLKCD-FL-XL-40ft/1000Z-38.12 31234.82713.1923.0001.7697.820

KCD-ST – double-walled storage tank container, CSC-ISO

Double-walled storage tank container with CSC-ISO transport frame.

ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
KCD-ST-ISOKCD-ST-10-DZ-38.12 312
KCD-ST-20-DZ-38.12 312
KCD-ST-40-DZ-38.12 312
KCD-ST-10-EXZ-38.12 312
KCD-ST-20-EXZ-38.12 312
KCD-ST-40-EXZ-38.12 312
KCD-ST-10-HC-DZ-38.12 312
KCD-ST-20-HC-DZ-38.12 312
KCD-ST-40-HC-DZ-38.12 312
KCD-ST-10-HC-EXZ-38.12 312
KCD-ST-20-HC-EXZ-38.12 312
KCD-ST-40-HC-EXZ-38.12 312

KCD-MA – double-walled storage tank container, integrated machine room

Double-walled storage tank container with integrated machine room.

ViewItem No.AuthorizationVolumeTotal lengthTotal widthTotal heightWeightDownloadContact
lmmmmmmkgPDFMail
KCD-MAKCD-MA1-20-HC-DZ-38.12 312
KCD-MAKCD-MA1-30-HC-D
KCD-MAKCD-MA1-40-HC-D
KCD-MAKCD-MA1-20-HC-EX
KCD-MAKCD-MA1-30-HC-EX
KCD-MAKCD-MA1-40-HC-EX
KCD-MAKCD-MA2-20-HC-D
KCD-MAKCD-MA2-30-HC-D
KCD-MAKCD-MA2-40-HC-D
KCD-MAKCD-MA2-20-HC-EX
KCD-MAKCD-MA2-30-HC-EX
KCD-MAKCD-MA2-40-HC-EX
KCD-MAKCD-MA4-40-HC-D
KCD-MAKCD-MA4-40-HC-EX

Storage tanks and storage tank containers – current articles:

Oversized diesel storage tank with thermal insulation

Oversized diesel storage tank with thermal insulation

Thermally insulated, double-walled diesel tank container as a custom-made product including diesel cleaning system in final assembly before delivery.
Container tank system

Container tank system

The container tank system (special tank) is a compact storage tank for a wide variety of media. It is equipped with a suction system consisting of a central suction pipe and five separate suction outlets...
Shallow double-walled storage tank container

Flat storage tank container

Flat double walled 40 ft. storage tank container before delivery. Sub base tank for accommodating generators in machine containers, for example...
Diesel tank storage tank oversized with thermal insulation

Diesel tank storage tank oversized

Double-walled storage tank container, custom-made including diesel cleaning system, volume: 40.000 liters, L x W x H: 5.990mm x 3.800mm x 2.996mm
Krampitz flat double-walled fuel storage tanks KTD-FL

Extra-flat storage tank KTD-FL

Flat double-walled fuel storage tanks KTD-FL made of stainless steel or steel for supplying machines and units with diesel or heating oil from 2.000 liters to 12.000 liters
Krampitz double-walled storage tanks KTD

Krampitz double-walled storage tanks KTD

  Our double-walled storage tanks KTD are made of stainless steel…

HVO 100 Diesel in Germany, forecast and filling station network

HVO 100 Diesel, also known as Hydrotreated Vegetable Oil 100,…
Krampitz single-walled storage tanks KTE

Krampitz single-walled storage tanks KTE

  Our single-walled storage tanks KTE are made of stainless steel…

HVO (Hydrotreated Vegetable Oil) – Benefits

HVO Diesel, or Hydrotreated Vegetable Oil Diesel, enjoys…

KTD-F 10000 liter diesel tank

Diesel storage tank as supply tank for emergency diesel power systems …
KTD-FA-7000 storage tanks with thermal insulation

KTD-FA-7000 storage tanks with thermal insulation

KTD-FA-7000 Storage tanks with thermal insulation for storing…
HVO 100 renewable diesel

HVO 100 – vegetable diesel

HVO 100, also known as Hydrotreated Vegetable Oil 100 or…
Urea tank 10ft for storage of urea

Storage of urea

Urea tank in special equipment with a roof mounted…

Steel flood tank

Flood tank made of steel Extra narrow steel tank for use…
Steel diesel storage tank

Storage tank for storing diesel

Fully insulated steel storage tank for storing diesel Diesel storage tank…

Heavy storage tank for sea transport of methanol

Double-walled methanol tank with operating pressure 1,5 bar Solid…
Two-chamber tank thermally insulated diesel and urea

Thermally insulated two-chamber tank

Thermo-insulated two-chamber tank KTD-F-7500 Special two-chamber tank…
Diesel storage tank as an emergency tank farm

Diesel storage tank as an emergency tank

Diesel tank container KTD-F-20000 thermally insulated with protective cabinet…
Stainless steel urea tank

Stainless steel urea tank

Krampitz KTE-F special - urea storage tank stainless steel tank 12000…
Base tank for generators

Base tank for generators

Flat steel storage tank as a base tank for a generator A…

Steel urea storage tank

Urea storage tank made of steel with thermal insulation Steel tank…
Steel diesel storage tank with thermal insulation

Steel diesel storage tank

Double-walled diesel storage tank made of steel with thermal insulation. The KTD-F-96 is a double-walled steel storage tank with thermal insulation for the storage of diesel.

Storage tank for fresh oil and used oil

Storage tank for fresh oil and used oil for use as a stacking unit in...
Krampitz large tank farm

Large tank farm test setup

Krampitz large tank farm before test setup in the factory Test setup for…
Flood proof diesel storage tank

Flood proof diesel storage tank

Flood-proof diesel storage tank type 40ft HC-HW This…
chemical waste collector - storage tank

Chemical waste tank container

Krampitz Chemical Waste Collector KCWC-20000 Automatic Chemical Collector…
Tanks for bottling plants

Tanks and tank system solutions for bottling companies

Modern, contemporary tanks and tank systems for the provision…
generator base fuel tank

Generator belly tanks – the KTD-FL tank series

Generator belly tanks - the tank series KTD-FL and KTD-FL-Mini as "mini flounders" ...
Storage tank 1000 liters of urea

Storage tank KTD-F 1000 liters of urea

Storage tank KTD-F 1000 liters urea The smallest member of the…
Petroleum storage tank XXL

Petroleum storage tank

Extra-large storage tank / process tank for petroleum and other water-polluting…

Construction site unit series

Series of construction site units Presentation Concept: Construction site units Krampitz…
Krampitz container variant 1x 5ft + 1x 10ft + 1x 5ft = 1x 20ft
double-walled high cube storage tanks for large power plants

Double-walled high cube storage tanks for large power plants

Special double-walled highcube storage tanks for the assembly…
KTD-F 30000 liter heating oil storage tank

Heating oil storage tank 30000 liters with thermal insulation

Krampitz storage tank type KTD-F 30000 special with thermal insulation An…
Industrial emissions

Technical requirements from the 44th BImSchV

Technical requirements for power generation plants such as NEA…
oversized storage fuel tank

Oversized tank modules up to 100.000 liters

Oversized tank modules with volumes of approx. 75.000 to 100.000…
double-walled machine tanks

Machine tanks for gas power plants

Double-walled machine tanks for gas power plants (100 MW units) storage tanks…
Krampitz DIBt approvals info

Krampitz storage tank series – approvals

Information sheet: Restructuring of our previous DIBt approval Z-38.12-23 for double-walled steel storage tanks, as well as the presentation of our new DIBT approval Z-38.12-312 for double-walled steel storage tanks with and without ISO container frames for extreme as well as normal installation, operating and application conditions.
KTD-F tank diesel 20.000 liters

KTD-F tank, diesel, 20.000 liters

KTD-F Tank, Diesel, 20.000 Liter Storage Tank for Earthquake Zone…
KSS tank - storage tank for cooling lubricants

KSS tank – cooling lubricant storage tank

Disposal container (KSS tank) for used cooling lubricants…
Flat tank container with thermal insulation for the construction of machine containers

Tank container KCD-FL as a thermally insulated foundation tank for plant construction

Flat tank container with thermal insulation as a custom-made product...
fuel tank farm

Krampitz large tank farm – how it works

How does the Krampitz large tank farm work? How is the fuel…
Krampitz foundation tank Flounder

Foundation tank for plant construction

Foundation tank with a load-bearing steel structure for plant construction. Presentation of the foundation tank KCD-FL "Flounder" ...
Storage tank clusters

Krampitz large tank / storage tank cluster

Krampitz Large Tank - Storage Tank Cluster for Mining, Industry,…

The importance of fuel supply logistics for the technical development of a region

The people who live on 60% of the Earth's landmass...
Krampitz Universal tank container Norway

Krampitz Tanksystem GmbH Documentation installation of universal tank containers in Norway

Documentation about the delivery and installation of an above-ground...
Thermally insulated storage tanks

Cope with summer and winter temperatures with thermally insulated tanks

Thermally insulated storage tanks are suitable for high and low outside temperatures…
Storage tank containers

Tanks and tank systems for mechanical engineering

Modern mechanical engineering relies on a permanent and reliable supply of media. Lubricants, fuels, coolants and additives for exhaust gas purification must be available locally and always in sufficient quantities.

Urea storage – Krampitz storage tanks

With the addition of urea, diesel engines become just as clean and environmentally friendly as gasoline engines.

Animation of a Krampitz container system for CHP systems

Krampitz as a supplier of container and machine housings…
Storage tank containers – double-walled tank containers

Storage tank containers – double-walled tank containers

The double-walled storage tank containers are the ideal addition to the mobile gas station container system, allowing the tank depot to be expanded practically indefinitely.
Tank construction chemical industry

Storage tanks for the chemical industry

BASIS® storage tank - chemistry. Storage tanks for the chemical industry from Krampitz.

Tank systems from Krampitz Tanksystem GmbH

Order tank containers from a specialist! Krampitz Tanksystem GmbH offers demanding customers innovative container solutions that guarantee the highest level of reliability and safety.

Krampitz gas station containers, office and shop containers in Saudi Arabia

Gas station container from Krampitz Tanksystem GmbH again after…