• Link to Facebook
  • Link to X
  • Link to Instagram
  • Link to Youtube
  • Link to Mail
  • News
  • Downloads
  • Jobs
  • Contact
Phone: +49(0)3901/3088-100 | E-mail: info@krampitz.de
Tank systems & tank containers manufacturer | Krampitz Tanksystem GmbH
  • Machine fuel tanks
    • Day tanks (single and double walled)
      • TTE-A (100 – 1.950 liters, single-walled)
      • TTE-B (100 – 990 liters, single-walled)
      • TTE-C (1.500 + 1.950 liters, single-walled)
      • TTE-XL (2.500 – 5.000 liters, single-walled)
      • KTD-TT (250 – 990 liters, double-walled)
      • Day tank accessories
    • Storage tanks (double-walled)
      • KTD (950 – 50.000 liters)
      • KTD-FA (Outdoor installation)
        • KTD-FAA (1.000 – 40.000 liters)
        • KTD-FAB (1.000 – 40.000 liters, thermal insulation)
        • KTD-FAC (1.000 – 40.000 liters, urea)
        • KTD-FAE (1.000 – 40.000 liters, urea, thermal insulation)
      • KTD-FI (Indoor installation)
        • KTD-F-I-A (1.000 – 40.000 liters)
        • KTD-FIB (1.000 – 40.000 liters, thermal insulation)
        • KTD-FIC (1.000 – 40.000 liters, urea)
        • KTD-FIE (1.000 – 40.000 liters, urea, thermal insulation)
      • KTD-F-XL (Outdoor installation)
        • KTD-F-XL-AA (50.000 – 100.000 liters)
        • KTD-F-XL-AB (40.000 – 80.000 liters, thermal insulation)
        • KTD-F-XL-AC (50.000 – 100.000 liters, urea)
        • KTD-F-XL-AE (40.000 – 80.000 liters, urea, thermal insulation)
    • Storage tanks (earthquake zone, flooding)
      • KTD-F-XL (Earthquake Zone 1, Outdoor Installation)
        • KTD-F-XL-AD (50.000 – 100.000 liters)
        • KTD-F-XL-AF (40.000 – 80.000 liters, thermal insulation)
        • KTD-F-XL-AG (50.000 – 100.000 liters, urea)
        • KTD-F-XL-AH (40.000 – 80.000 liters, urea, thermal insulation)
      • KTD-FE-A (Earthquake Zone 1-3, Outdoor Installation)
        • KTD-FE-AD (1.000 – 40.000 liters)
        • KTD-FE-AF (1.000 – 40.000 liters, thermal insulation)
        • KTD-FE-AG (1.000 – 40.000 liters, urea)
        • KTD-FAH (1.000 – 40.000 liters, urea, thermal insulation)
      • KTD-FE-I (Earthquake Zone 1-3, Indoor Installation)
        • KTD-FE-ID (1.000 – 40.000 liters)
        • KTD-FE-IF (1.000 – 40.000 liters)
        • KTD-FE-IG (1.000 – 40.000 liters)
        • KTD-FE-IH (1.000 – 40.000 liters)
      • KTD-FHW (flood protection, outdoor installation)
        • KTD-FHW-A-D (5.000 – 20.000 liters)
        • KTD-FHW-AH (5.000 – 20.000 liters, thermal insulation)
    • Storage tank container (double-walled)
      • KCD-FL (7.200 – 27.800 liters, flat belly tank)
      • KCD-FL-XL (9.000 – 34.800 liters, flat extra-large belly tank)
      • KCD-ISO-HC (13.000 – 60.000 liters, CSC-ISO, flood protection, thermal insulation, earthquake zone 1)
      • KCD-MA (7.500 – 40.000 liters, engine room, flood protection, thermal insulation, earthquake zone 1)
      • KCD-ST-HC (stackable)
  • Gas station container
    • KCC (COMPACT) – gas station container
    • KCM (MULTI) – gas station container
    • KCU (UNIVERSAL) – gas station container
    • KC-P (fuel pump platform)
    • KC-DM (roof module)
    • KC-O/S (office / shop module)
    • KC-MA (engine room module)
    • KC-ST (tank module)
  • Transport tanks
  • Tank farms
  • Stacking systems
  • Equipment
    • Pumps & Accessories
    • Day tank accessories
    • Oil supply facilities
    • Security features
  • Click to open the search input field Click to open the search input field Search
  • Menu Menu

TTE day tank equipment package Eisenach and flow diagrams

The TTE Eisenach equipment package contains three level sensors and a filling nozzle. They can do that TTE day tanks can be filled manually with a fuel nozzle using a tank truck.

A collecting tray is required for setting up the single-walled tanks. If none are available on site, our collection trays, which are specially designed for the tanks, and our columns can be used.

Now screw in the filler neck and the day tank can be filled manually using the nozzle.

By the way! Here you can clearly see how the tank's own mechanical content display with float arm works. If the level rises, the float arm rises and transfers the movement to the pointer.

The consumer is supplied via the supply line.
The flow connection is one centimeter above the bottom of the tank.

This means that dirt and deposits, which mainly collect on the floor, do not get into the flow line.

However, the tank can be completely emptied using the KFE tap on the right.

Danger! The piping is not included in the equipment package.
But there are 3 level sensors with which fill levels are recorded electrically. These switching contacts can be connected to an external control to display the filling levels. Or for automatic refilling with a system-specific refill pump type Z-PK.

The control records three fill level points: min-min, min and max. When the fill level in the tank reaches the min level, the refill pump starts and fills the tank. When the max level is reached, the pump switches off again. The tank is full.

If the fuel level drops to min-min, i.e. only 10% fill level and the tank is almost empty, the unit control switches the machine off. This prevents the machine from running dry and drawing air.

Easy filling and level control with the TTE Eisenach equipment package.

Krampitz tank system - cubically good.

Keywords: drip tray, Equipment, Filling neck, Level, Krampitz, Level indicator, Package Eisenach, residual emptying, Controller, Day tank, storage tank
https://www.krampitz.de/wp-content/uploads/2023/10/TTE-Tagestank-Ausstattungspaket-Eisenach.jpg 850 1506 krampitz.de https://www.krampitz.de/wp-content/uploads/2023/06/krampitz-uni.png krampitz.de2023-10-11 16:40:162023-12-05 12:32:50TTE day tank equipment package Eisenach and flow diagrams
You might also be interested in
Krampitz double-walled day tanks TTD Krampitz double-walled day tanks KTD-TT (old: TTD)
Storage tank clusters Krampitz large tank / storage tank cluster
Day tanks TTE Krampitz single-walled day tanks TTE
Krampitz tank container with roof structure and lighting The future of gas stations
Krampitz double-walled storage tanks KTD Krampitz double-walled storage tanks KTD
tank container KCU Tank container KCU

Latest Posts

  • Diesel boat refueling station - safe bunkering solutions for shipping
    Diesel boat refueling station – a safe bunkering solution for shipping
  • Fueling station containers as airfield fuel stations
    Tank containers as airfield refueling stations
  • Krampitz Petrol station system Africa Line
    Krampitz at UNITI expo 19-21 May 2026
  • Exhibition of tank systems and storage tanks at Krampitz at a trade fair.
    Data Center World Frankfurt 2026
  • Large transport vehicle in the warehouse for tank systems and storage tanks.
    Double-walled mining tank container Pegasus 6000
  • Turnkey tank systems with storage tanks and transport solutions.
    Weatherproof, non-flammable battery housing for Varta lithium batteries
  • Robust tank container for storing, transporting and warehousing liquids.
    cargo benches
  • Large, white storage container housing with open lid, suitable for tank systems.
    Vacuum chamber with large locking door
  • Tank systems, storage tanks and transport systems for industrial applications.
    KTD-4500 sterile tank version with diesel filtration system
  • Compact tank systems for storage and transport in a robust housing.
    KRP in weatherproof housing – fuel preparation

request form

Contact us here:

    *Privacy Policy
    I have read the [Privacy Policy read and agree.

    *Please fill out the mandatory fields at least.

    MINOTAUR® tank containers

    Krampitz MINOTAUR® tank container Krampitz MINOTAUR® tank container are robust, highly secure, quickly assembled container systems with extensive international approvals. They are used in all areas of professional fuel supply.

    Applications: Petroleum distribution, military, mining, construction industry, aid organizations, logistics and shipping companies

    Media: Diesel, gasoline, kerosene, biodiesel, bioethanol, vegetable oil

    BASIS® day tanks and storage tanks

    Krampitz BASIS® tanks Krampitz BASIS® storage tanks are single-walled or double-walled day tanks and storage tanks. A high safety standard allows it to be used in all industrial areas as a day tank and storage tank, for example as a diesel tank, gasoline tank, oil tank, kerosene tank, heating oil tank, vegetable oil tank.

    Temperature range: -10 ° C to + 55 ° C

    Volume: 50 to approx. 100.000 liters

    CENTAUR® transport tank

    Krampitz CENTAUR® transport tank Krampitz CENTAUR® transport tank and storage tank container double-walled for diesel, gasoline, kerosene and lubricating oil – safe, reliable and highly flexible. Our tanks are known for extreme stability, high safety and very good usability. They are used worldwide on all continents. Our mining containers are considered “indestructible”.

    In addition to robustness, variable loading options and increased corrosion protection of the floor and roof assembly were taken into account.

    EQUIPMENT® for tank systems

    Krampitz EQUIPMENT® Krampitz EQUIPMENT® for tank systems: Pumps (fuel pumps, oil pumps) and tank accessories (level sensors) for pumping or suctioning thin to lubricating media.

    Special pumps on request:
    – Transfer pumps with high delivery rates of up to 1000 liters/min.
    – heated pumps
    – Explosion-proof pumps (ATEX)
    – Pumps for special liquids
    – Pumps for dispensing systems

    Headquarters

    Krampitz Tanksystem GmbH
    Lüneburger Straße 7
    21368 Dahlenburg/LG
    Phone: +49(0)3901/3088-100
    Fax: +49(0)5851 / 9443-21

    Sales

    Salzwedel branch
    Siedlung des Friedens 40
    29410 Hansestadt Salzwedel

    Phone: +49(0)3901/3088-100
    Mobile: +49(0)172-7714414
    Fax: +49(0)3901/3088-131
    Email:  info@krampitz.de

    Mon - Thu: 7.00 a.m. - 16.15 p.m.
    Fri: 7.00 a.m. - 13.15 p.m.

    Interesting

    • Downloads
    • Gallery
    • About us
    •  F.A.Q.
    • Sitemap
    • Catalogue
    • Shop Tank Equipment

    Information

    • Contact
    • Become a service partner
    • Job Offers
    • Privacy Policy
    • General terms and conditions
    • Imprint
    ©2026 www.krampitz.de
    • Link to Facebook
    • Link to X
    • Link to Instagram
    • Link to Youtube
    • Link to Mail
    Nach oben scrollen Nach oben scrollen Nach oben scrollen
    Accessibility adjustments

    Presented by OneTap

    How long should the toolbar be hidden?
    Duration of toolbar hiding
    Choose your accessibility profile
    Mode for the visually impaired
    Improves the website's appearance
    Profile for seizure-proof display
    Removes flashes and reduces color
    ADHD-friendly mode
    Focused browsing, without distractions
    Blindness mode
    Reduces distractions, improves concentration
    Safe mode for epilepsy
    Dim the colors and stop the flashing
    Content modules
    font size

    Standard

    Row height

    Standard

    Color modules
    Orientation modules
    Phone number
    × qcwpbotmodal-content